The MACONS Industrial RO system is engineered as per the client's requirements and in accordance to the standards & requirements of the particular industry it will serve. This MACONS RO system is ideal for different types of industrial setups that required treated water. The MACONS industrial RO system is not only highly effective but also easily maintainable. These can be cleaned with ease and operated continually. The systems are cost effective and reliable.

DESCRIPTION 2000 lit 5000 lit 10000 lit
MULTIGRADE SAND FILTER (SS OPTIONAL)
Maximum Flow Rate. 5000 lit/hr. 10000 lit/hr. 20000 lit/hr.
Minimum Flow Rate 4000 lit/hr. 9000 lit/hr. 19000 lit/hr.
Maximum Working Pressure 3.5 kg/cm2. 3.5 kg/cm2. 3.5 kg/cm2.
Minimum Working Pressure 2.0 kg/cm2. 2.0 kg/cm2. 2.0 kg/cm2.
Period between backwashes 24 hrs. 24 hrs. 24 hrs.
Backwash Duration 10 - 15 mins. 10 - 15 mins. 25-30 mins.
Maximum Inlet Suspended Solids 25 NTU 25 NTU 25 NTU
Source of Backwash Water Raw water with turbidity within 25 NTU. Raw water with turbidity within 25 NTU. Raw water with turbidity within 25 NTU.
 ACTIVATED CARBON FILTER (SS OPTIONAL)
Maximum Flow Rate. 5000 lit/hr. 10000 lit/hr. 20000 lit/hr.
Minimum Flow Rate. 4000 lit/hr. 5000 lit/hr. 19000 lit/hr.
Maximum Working Pressure 3.5 kg/cm2. 3.5 kg/cm2. 3.5 kg/cm2.
Minimum Working Pressure 2.0 kg/cm2. 2.0 kg/cm2. 2.0 kg/cm2.
Period between backwashes 24 hrs. 24 hrs. 24 hrs.
Backwash Duration 10 - 15 mins. 10 - 15 mins. 25-30 mins.
Maximum Inlet Suspended Solids 25 NTU 25 NTU 25 NTU
Source of Backwash Water Filtered water. Filtered water. Filtered water.
REVERSE OSMOSIS SYSTEM
Permeate Flow  1900-2000 lit/hr. 4500-5000 lit/hr. 9500-10000 lit/hr.
Average Recovery  50% 50% 50%
Membrane Dia - inches  8.0 8.0 8.0
Membranes 2 No. 5 No. 10 No.
Average TDS removal 90 - 95 % 90 - 95 % 90 - 95 %
High Pressure Pump Type Centrifugal Type - SS Centrifugal Type - SS Centrifugal Type – SS
Drive motor Hp/RPM 3.0 HP 5.5 HP 10.0 HP
Raw Water Pump 2 HP 3.5HP 7.5 HP
Power Supply 220 V / 50 Hz 415 V / 50 Hz 415 V / 50 Hz
CHEMICAL DOSING SYSTEM
Dosing Pump 0-6 LPH 0-6 LPH 0-6 LPH
ULTRAVIOLET
Ultraviolet System 3 lamps of 18 watts with power Box. 3 lamps of 39 watts with power Box. 3 lamps of 60 watts with power Box.
OZONE GENERATOR
Ozonator 5 gms/hr. 10 gms/hr. 20 gms/hr.

  • Backwash Automatic.
  • Raw Water Sensor.
  • Treated Water Sensor.
  • Online TDS Meter.
  • All Parts/Internal Piping in SS 304.
  • PLC Control.
  • Standby High Pressure Pump, Raw Material Pump & Ozone Generator (Optional).
  • To Increase TDS, as per the client requirement.