Air Gas

Oxygen Concentrator

Oxygen Generator

Oxygen Plant

Nitrogen Generator

Nitrogen Plant

Ozone Generator

OZONE GENERATOR

MACONS OXY-O3 ozone generators employ the corona discharge principle. Properly dried air, or oxygen itself, is passed between a high-voltage electrode and ground electrode separated by a dielectric material. Considerable electrical energy is required for the ozone producing electrical discharge field to be formed.

Model MCO-A025G MCO-A5G MCO -10G MCO -20G MCO-30G MCO-60G MCO-100G
Housing Standard - - Ip55 Ip55 Ip55 Ip55 Ip55
Input Voltage Supply 220V / 110V 220V / 110V 220V / 110V 220V / 110V 220V / 110V 220V / 110V 220V-50HZ
Power Consumption 450 W 450 W 650W 780 W 1190W 1740W 3200W
Technology Applied Corona Discharge Corona Discharge Corona Discharge Corona Discharge Corona Discharge Corona Discharge Corona Discharge
Electrode Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Dielectric Substance Silicate Glass Silicate Glass Silicate Glass Silicate Glass Silicate Glass Silicate Glass Silicate Glass
Gas Source Ambient Air Ambient Air Oxygen Oxygen Oxygen Oxygen Oxygen
Ozone Out put 2.5 gram/hr 5 gram/hr 2-10 gram/hr 4-20 gram/hr 6-30 gram/hr 30-60 gram/hr 20-100gram/hr
Input Flow Rate 3 Liter/min 5 Liter/min 3 Liter/min 5 Liter/min 8 Liter/min 12 Liter/min 25 LPM
Ozone Concentration 15-20 mg/l 15-20 mg/l 50-60 mg/l 60-70 mg/l 60-70 mg/l 80-85 mg/l 75-115 mg/l
Cooling Method Air / Water Air / Water Air / Water Air / Water Air / Water Air / Water Air / Water
Cooling Water Flow Rate NA NA NA >20 L/hr >30 L/hr >60 L/hr >100 L/hr
Case Material Clad Steel Clad Steel Clad Steel Clad Steel Clad Steel Clad Steel Clad Steel
Dimension(mm) 530*420*800 530*420*800 690*590*1360 690*590*1360 690*590*1360 690*590*1360 680*460*1150
Net Weight 40 Kg 45 Kg 108 Kg 116 Kg 126 Kg 137 Kg 155 Kg

  • IP 55 enclosure, it is weather proof for outdoor usage
  • It combines both water and air cooling to Ozone generator, in order to achieve the best performance for Ozone concentration.
  • In Built – Air compressor.
  • In Built – Oxygen concentrator to product oxygen feed into Ozone generator, in order to get higher Ozone concentrator.
  • In Built – Condenser cooling air before deliver air into Oxygen generator.
  • In Built – Air dryer to dry air before deliver air into Oxygen generator.
  • In Built – Double stage air filtration to clean air before deliver air into Oxygen generator.
  • In Built – Temperature sensor, to cut off Ozone generator power supply to protect Ozone generator over heat.
  • In Built – Water flow sensor, automatic shutdown, if no water for cooling.
  • Automatic Operation – Machine operation selectable between manual and timer control.
  • Timer control fully automatic 24 hours day, 7 days a week.